Perfect for environmental and offline process monitoring applications

  • High sample throughput in liquid and solid mode 

  • Variable injection and sample digestion techniques 

  • Highest matrix tolerance and cost efficiency 

Fast and easy-to-determine parameters have established TOC and TNb levels as reliable indicators for quality assessment of water samples in environmental monitoring and industrial processes. The TOC parameter is equally important for the classification of solid waste in terms of landfill class allocation. 

The multi N/C series offers optimized instrument solutions for a wide range of requirements in these areas, with which you can determine TOC/TNb contents efficiently and reliably and work in compliance with standards. Application fields covered include the analysis of drinking and surface water, landfill leachates andwaste water, process water, such as cooling and boiler feed water, electrolysis baths or as QC in the chemical industry. But also the constantly growing sample numbers of soils, sludges and sediments as well as industrial waste, ashes, slags and filter dusts can be analyzed for TOC fully automatically.

Efficiency and high throughput
Automate your processes with versatile auto samplers and other efficiency-enhancing features such as integrated sample homogenization by magnetic stirring, automatic acidification and parallel purge and analysis. Depending on your requirements, processes can be optimized from samplers for small sample sequences to automation solutions with a capacity of up to 146 samples for high-throughput analysis. 

With a separate solids module, you can also analyze solid samples directly for their TOC content. Thanks to built-in valve technology, you can quickly switch between liquid and solid operation without downtime for system conversion. With the multi N/C duo systems not only water analysis but also TOC solids analysis with up to 48 samples per sequence can be automated. Large sample weights ensure reliable measurements even for less homogeneous samples. 

 

 

Long service life thanks to proven furnace technology
The catalytic high-temperature combustion at up to 950 °C enables the complete oxidation of stable organic water contaminants and particle-containing samples as well as simultaneous TNb  determination. Efficiency and reliability characterize our furnace technology in this field. We can proudly offer a 10-year long-term warranty* on our furnace technology. In addition, the optimized design of the combustion tubes minimizes the use of expensive catalysts and simultaneously increases tolerance to saline matrices. In solids analysis, we rely entirely on durable ceramic technology. High combustion temperatures of up to 1300°C make the use of expensive catalysts obsolete.  We thus offer you extended maintenance cycles and minimized operating costs, both, in the analysis of water and solids.

Our models for environmental and process analysis

 multi N/C 2100Smulti N/C 3100multi N/C UV HSmulti N/C 2100S duomulti N/C 3100 duo

High temperature combustion up to 950 °C

xx-xx

UV/Persulfate (254 nm, 185 nm)

--x--

Flow injection

-xx-x
Direct injectionx--x-

Measuring range [mg/l] TC/TOC/NPOC/TIC

0 – 30,0000 – 30,0000 – 10,0000 – 30,0000 – 30,000

Measuring range TNb mg/l (ChD)

0 – 1000 – 10,0001)-0 – 1000 – 10,0001)

Measuring range TNb mg/l (CLD)

0 – 2000 – 20,0001)-0 – 2000 – 20,0001)

HT 1300 soldis module

xxxxx

Double Furnace solids module

x----

Automated HT 1300 (up to 48 solid samples)

---xx

Measuring range [mg] abs. solid TC/TOC

0 – 500

0 – 5000 – 5000 – 5000 – 500

Self Check System

xxxxx

VITA/Easy Cal

xxxxx

1) Dilution ratios of up to 1:100 are possible through automatic external dilution with AS vario/ / AS vario ER.

  If you are still not sure which model fits best to your requirements - use our device finder.

multi N/C 2100S – the power package

The compact and robust routine analyzer based on high-temperature combustion with integrated autosampler and septum-free injection technology is ideal for particle- or oil-containing samples as well as very small sample volumes.

Characteristics of the multi N/C 2100S:

  • Valve-free direct injection technology
  • Suitable for very small sample volumes
  • Optimum particle handling capability and rinsing efficiency
  • Compact system with integrated, fully automatic autosampler

multi N/C 3100 – Versatility at the highest level

The fast all-rounder for all samples thanks to a combination of catalytic high-temperature combustion and flow injection with intelligent rinsing technology and robust ceramic injection valve for particle-containing samples. The high-precision dosing unit allows precise dosing of a wide range of volumes.

Characteristics of the multi N/C 3100:

  • Flow injection with intelligent rinsing technology for samples containing particles
  • Ceramic injection valve for high robustness
  • High detection sensitivity
  • High sample throughput by parallel purge and analysis for NPOC mode

 

multi N/C UV HS – TOC determination made easy

The highly sensitive TOC analyzer combines wet chemical UV digestion with a particularly effective UV radiation source (with 3-year warranty) and variable, high-precision sample dosing of high injection volumes (up to 20 ml) according to the flow injection principle.

Characteristics of the multi N/C UV HS:

  • Wet chemical oxidation with High Power, Long Life UV Reactor
  • Flow injection with high sample throughput by parallel purge and analysis in NPOC mode
  • Highest sensitivity and precision in the ppb range
  • TOC determination even in aggressive matrices

 

multi N/C 2100S duo – whether solid or liquid – robust automation 

The robust routine analyzer based on high-temperature combustion with septum-free injection technology is ideal for particle- or oil-containing water samples as well as very small sample volumes. It has a high degree of automation for both water and solids analysis.

Characteristics of the multi N/C 2100S duo:

  • Carry-over free direct injection technology 

  • Suitable for very small sample volumes 

  • Robust, catalyst-free solids TOC measurement 

  • Fast switch-over from liquid to solid mode without system conversion 

 

multi N/C 3100 duo – whether liquid or solid – highest sample throughput 

The fast all-rounder for all samples thanks to a combination of catalytic high-temperature combustion and flow injection with intelligent rinsing and injection technology for particle-containing water samples. Highest sample throughput by parallel purge and analyzing in liquid mode and low sample preparation effort for solids. 

Characteristics of the multi N/C 3100 duo:

  • Flow injection with intelligent rinsing and injection technology for samples containing particles 

  • High sample throughput by parallel purge and analysis in NPOC mode 

  • Robust, catalyst-free solids TOC measurement 

  • Fast switch-over from liquid to solid mode without system conversion 

 

Downloads

Brochure multi N/C (English)

Open PDF

multi N/C Series – Find the Right TOC Analyzer for Your Needs (Englisch)

Open PDF

TechNote multiNC FR-NDIR Detector (English)

Open PDF

Contact us We are happy to help you and will contact you as quickly as possible.