CA79 TOC Series The low-range online TOC analyzer
- Highest product and process safety due to early contamination detection
- Fast response times for immediate reaction and process protection
- High system availability thanks to maintenance-friendly design
- Compliance with European and US Pharmacopoeia requirements
A reliable online TOC analyzer for fast, continuous monitoring of ultrapure water and WFI, ensuring process safety, product quality and efficient batch release in the pharmaceutical industry.
Fast response times for real-time TOC monitoring in ultrapure water
The CA79 is an online TOC analyzer designed for process monitoring. It complies with the strict requirements of life science and pharmaceutical industries and delivers reliable, real-time monitoring of high-purity water systems, including WFI (water for injection), detecting even trace levels of organic contamination. CA79 requires only a sample flow rate of 14 mL/min and ensures consistent water quality and enables safe, efficient production processes. The robust analyzer offers a wide measuring range from 0.5 - 1000 µg/L (ppb) and features an integrated output relay for reliable collective alarm signaling. Serial number–specific IQ/OQ documentation ensures fast installation and on-site qualification.
- Fast response time (t90) of 50 seconds
- Optimized for ultrapure water applications (conductivity < 2 µS/cm)
- Proven UV oxidation without oxidizing agent combined with differential conductivity measurement
- Collective alarms for fault or limit exceedance via 4–20 mA
- Maintenance-friendly IP54-rated stainless steel housing
- Reliable service network for IQ, OQ and support
- 21 CFR Part 11 compliant data management with documentation and SSTs (system suitability tests)
Brochures
| Title | Language | Info |
|---|---|---|
| Brochure TOC Solutions for Pharma | en | PDF, 3 MB |
| Safe ultra-pure water for pure products | en | PDF, 615 KB |
| CA79 TOC analyzer / 21CFR Part 11 Statement | en | PDF, 610 KB |
| Data integrity based on ALCOA+ principles | en | PDF, 626 KB |
Advanced UV oxidation and differential conductivity for high-speed TOC analysis
CA79 applies the principle of differential conductivity detection. The analyzer can continuously read TOC sample levels with very fast response times of only 50 seconds (t90). Therefore, the analyzer is ideally suited to monitor especially time critical process steps in production, distribution and storage of ultrapure water or WFI in pharma and life sciences industries.
Sample digestion is performed by a high-power UV reactor utilizing two oxidation wavelengths simultaneously for fast and complete organic carbon oxidation. High-energy UV radiation at 185 nm and 254 nm are used to oxidize even extremely stable organic compounds completely to CO2 without any oxidizing agent.
Product Variants at a Glance
- CA97 TOC analyzer - Single channel with manual SST function
- CA97 TOC analyzer - Single channel with automated SST function
- CA97 TOC analyzer - Three channel with manual SST function
All product variants are available with and without detection of inlet pressure sample.
Main accessories...
CA79 applies the principle of differential conductivity detection. The analyzer can continuously read TOC sample levels with very fast response times of only 50 seconds (t90). Therefore, the analyzer is ideally suited to monitor especially time critical process steps in production, distribution and storage of ultrapure water or WFI in pharma and life sciences industries.
Sample digestion is performed by a high-power UV reactor utilizing two oxidation wavelengths simultaneously for fast and complete organic carbon oxidation. High-energy UV radiation at 185 nm and 254 nm are used to oxidize even extremely stable organic compounds completely to CO2 without any oxidizing agent.
Product Variants at a Glance
- CA97 TOC analyzer - Single channel with manual SST function
- CA97 TOC analyzer - Single channel with automated SST function
- CA97 TOC analyzer - Three channel with manual SST function
All product variants are available with and without detection of inlet pressure sample.
Main accessories available
- Pressure reducer to reduce inlet pressure sample < 0.5 bar
- Heat exchanger to reduce sample temperature < 50°C
- Various bottle connection kits to facilitate automatic SST function
Products
CA79 TOC analyzer - 3 channel with manual SST
The CA79 is a reliable online TOC analyzer for continuous monitoring of WFI and ultrapure water with a fast response time, enabling process safety, product quality standards and efficient batch release in the pharmaceutical industry.
Order number: 450-500.804
CA79 TOC analyzer - 3 channel with manual SST and inlet pressure detection
The CA79 is a reliable online TOC analyzer for continuous monitoring of WFI and ultrapure water with a fast response time, enabling process safety, product quality standards and efficient batch release in the pharmaceutical industry.
Order number: 450-500.805
CA79 TOC analyzer - Single channel with automated SST
The CA79 is a reliable online TOC analyzer for continuous monitoring of WFI and ultrapure water with a fast response time, enabling process safety, product quality standards and efficient batch release in the pharmaceutical industry.
Order number: 450-500.802
CA79 TOC analyzer - Single channel with automated SST and inlet pressure detection
The CA79 is a reliable online TOC analyzer for continuous monitoring of WFI and ultrapure water with a fast response time, enabling process safety, product quality standards and efficient batch release in the pharmaceutical industry.
Order number: 450-500.803
CA79 TOC analyzer - Single channel with manual SST
The CA79 is a reliable online TOC analyzer for continuous monitoring of WFI and ultrapure water with a fast response time, enabling process safety, product quality standards and efficient batch release in the pharmaceutical industry.
Order number: 450-500.800
CA79 TOC analyzer - Single channel with manual SST and inlet pressure detection
The CA79 is a reliable online TOC analyzer for continuous monitoring of WFI and ultrapure water with a fast response time, enabling process safety, product quality standards and efficient batch release in the pharmaceutical industry.
Order number: 450-500.801
Technical Data
Detector |
Sample Supply |
Precision |
Parameters |
Digestion Mode |
Limit of Detection |
Measurement Range |
Dimension (width x depth x height) |
|
|---|---|---|---|---|---|---|---|---|
|
CA79 TOC analyzer - 3 channel with manual SST |
Differential conductivity | continuous flow, approx. 14 mL/min. | +/- 0.5 μg/L (ppb) or 1 % | TOC | UV digestion (reactor with continuous function monitoring) | 0.1 µg/L | 0.0005 - 1.0 mg/L | 290 mm x 200 mm x 500 mm |
|
CA79 TOC analyzer - 3 channel with manual SST and inlet pressure detection |
Differential conductivity | continuous flow, approx. 14 mL/min. | +/- 0.5 μg/L (ppb) or 1 % | TOC | UV digestion (reactor with continuous function monitoring) | 0.1 µg/L | 0.0005 - 1.0 mg/L | 290 mm x 200 mm x 500 mm |
|
CA79 TOC analyzer - Single channel with automated SST |
Differential conductivity | continuous flow, approx. 14 mL/min. | +/- 0.5 μg/L (ppb) or 1 % | TOC | UV digestion (reactor with continuous function monitoring) | 0.1 µg/L | 0.0005 - 1.0 mg/L | 290 mm x 200 mm x 500 mm |
|
CA79 TOC analyzer - Single channel with automated SST and inlet pressure detection |
Differential conductivity | continuous flow, approx. 14 mL/min. | +/- 0.5 μg/L (ppb) or 1 % | TOC | UV digestion (reactor with continuous function monitoring) | 0.1 µg/L | 0.0005 - 1.0 mg/L | 290 mm x 200 mm x 500 mm |
|
CA79 TOC analyzer - Single channel with manual SST |
Differential conductivity | continuous flow, approx. 14 mL/min. | +/- 0.5 μg/L (ppb) or 1 % | TOC | UV digestion (reactor with continuous function monitoring) | 0.1 µg/L | 0.0005 - 1.0 mg/L | 290 mm x 200 mm x 500 mm |
|
CA79 TOC analyzer - Single channel with manual SST and inlet pressure detection |
Differential conductivity | continuous flow, approx. 14 mL/min. | +/- 0.5 μg/L (ppb) or 1 % | TOC | UV digestion (reactor with continuous function monitoring) | 0.1 µg/L | 0.0005 - 1.0 mg/L | 290 mm x 200 mm x 500 mm |
For more information about our products and possible variants, please refer to the technical documents or use our contact form.
Order Information
Order number |
Description |
|---|---|
| 450-500.804 | CA79 TOC analyzer - 3 channel with manual SST |
| 450-500.805 | CA79 TOC analyzer - 3 channel with manual SST and inlet pressure detection |
| 450-500.802 | CA79 TOC analyzer - Single channel with automated SST |
| 450-500.803 | CA79 TOC analyzer - Single channel with automated SST and inlet pressure detection |
| 450-500.800 | CA79 TOC analyzer - Single channel with manual SST |
| 450-500.801 | CA79 TOC analyzer - Single channel with manual SST and inlet pressure detection |
Overview
| CA79 pressure regulator | 450-900.803 |
| Kit CA79 bottle connection set for Schott bottles for SST and calibration | 450-900.802 |
| Kit CA79 bottle connection set for SST and calibration | 450-900.801 |
| Kit CA79 heat exchanger | 450-900.804 |
| 402-890.803 | Kit CA78/79 hose connectors |
| 402-890.805 | Kit CA78/79 inlet hose 6mm |
| 402-890.804 | Kit CA78/79 inlet/outlet hose |
| 402-890.802 | Kit CA78/79 tube for pump |
| 402-890.801 | Kit CA78/79 UV reactor |